Maintenance 8. Trouble Shooting
RC180 Rev.17 173
Controller Main
1001
Operation Failure.
Command parameter is invalid.
1002
Requested data cannot be accessed.
The data is not set up or the range is
invalid.
Check whether the target I/O, variables,
and tasks exist.
Enter the correct password.
Cannot execute with unsupported
version.
Use the correct version file.
1005
Cannot execute with invalid serial
Use the backup data for the same
controller to restore the controller
configuration.
Use the backup data for the same
controller to restore the controller
configuration.
Cannot execute with invalid
Controller connected with PC is not
Connect with a regular controller.
1008
Initialization failure. Failed to initialize
OP is not supported by the connected
controller.
Cannot execute in recovery mode.
Boot the controller as normal.
Cannot execute due to controller
initialization failure.
Restore the controller configuration.
1022
Cannot execute without the project
being open.
Open a project.
1023
Cannot execute while the project is
Cannot activate from remote.
Execution in Teach mode is prohibited.
1026
Cannot execute in Teach mode except
Cannot execute in Auto mode.
Change to the Program mode.
Cannot execute in Auto mode except
from the main console.
Change to the Program mode.
Does not allow Operation mode to be
changed.
Change to the Auto mode with a console
Cannot execute while tasks are
executing.
Stop the task and then execute.
1032
Cannot execute while the maximum
number of tasks are executing.
Stop the task and then execute.
1033
Cannot execute during asynchronous
motion command.
Execute after the motion ends.
1034
Asynchronous command stopped
during operation.
The asynchronous command already
stopped when the controller received a
stop command.
Cannot execute in Remote enable
except from the Remote.
The command cannot be executed by the
console except the remote I/O when
AutoMode output of the remote I/O is
ON.
Cannot execute in OP enable except
from the OP.