Stylus Photo R1900/R2880/R2000/R2000s/SC-P400 Series Revision I
SC-P400 Series Adjustment 221
4. Switch to service mode from the main menu screen: Click a point to show
in “O” of the
Figure 9-7
in the pointer of the mouse in turn.
5. Input “7777” in the “enter password” cell, then click [OK] button (the
password is fixed and cannot change).
Figure 9-7. Switching to service mode
6. Click [Start Calibration] icon in the main menu screen.
Figure 9-8. Screen of the starting calibration
For SC-P400 Series, the “Applied Calibration Data” list
cannot be referred to, because only the service mode is
available for the series.