CEM+ Procedures 37
Chapter 4
CEM+ Procedures
CEM+ Configuration Overview
Configuring a CEM+ from either the face panel via the LCD and buttons or the Sensor+ Connect web
interface are basically the same procedures done in the same order. The web interface is more intuitive
and you are able to make more changes simultaneously; making it a more efficient way to configure
the modules.
Refer to the LCD menu structures and web interface site map for navigation details.
Since there are nearly an infinite number (at least for practical purposes of counting them) of ways for
you to configure your racks and dimmers, the procedures in this section are intended to be building
blocks for you to use to configure your unique system.
The headings for each procedure will contain either a [Power], [User] or a [Guest] to denote the
minimum required access level. [Web] or [FP] will note whether a specific navigation path is for the
web interface or the CEM+ face panel.
Configuration Procedures
Configure Your Computer for an ETCNet2 Network
Prior to changing any Network settings on your personal computer, record the current settings in the
following spaces below.
To use your personal computer on an ETCNet2 network that does not use a network router (i.e. hub
and/or switch only), ETC recommends the following default settings:
Each additional computer on an ETCNet2 network must have it’s own IP address which must be
different from any other computer on the same ETCNet2 network. Select from the following default
range of IP addresses for an additional personal computer on the network:
10.101.1.101 thru 10.101.1.249
IP Address _____._____._____._____
Subnet Mask _____._____._____._____
Gateway IP _____._____._____._____
IP Address 10.101.1.101
Subnet Mask 255.255.0.0
Gateway IP 10.101.1.101
Note:
If you are setting this computer up to be an FTP server, set the IP address to
10.101.101.117, the default FTP server IP address of CEM+ modules.
If you have a network that does include a network router, you must set the Gateway
IP address to the appropriate port on the router.