Do you have a question about the ETC sensor+ CEM+ and is the answer not in the manual?
Explains how to use this manual and lists symbols used for warnings.
Lists changes and new features introduced in version 3.1 of the system.
Details the components that make up the Sensor+ system, including racks and modules.
Explains the function and configuration capabilities of the CEM+ control module.
Provides an overview of the web server interface for system configuration and monitoring.
Details features like playback of presets and feedback capabilities.
Explains how the CEM+ uses the ACN priority scheme to arbitrate input priorities.
Lists the maximum limits for racks, dimmers, presets, rooms, and other system parameters.
Describes the buttons and LCD display on the CEM+ face panel for navigation.
Covers basic operation, including login levels and main menu navigation.
Explains the NoConfig menu for initial base settings and configuration creation.
Provides status information about dimmers, racks, network, and group.
Details how to log in using user levels and PINs for system access.
Explains how to set dimmer firing mode, curve, scale, and preheat properties.
Describes how to enable/disable data ports and create the patch for input ports.
Defines how the system responds to DMX, EDMX, and sACN data loss.
Explains how to add additional racks to the existing system configuration.
Details how to activate, deactivate, record, and edit presets within rooms.
Covers activating, deactivating, recording, and clearing panic looks.
Explains how to record dimmer loads for Advanced Features systems.
Provides an overview of the web interface, its capabilities, and access methods.
Covers group management, including summary status and dimmer checks.
Allows access and setting of properties for all racks and dimmers in the configuration.
Details how to configure individual rack properties and settings.
Provides a single place to set all dimmer properties like mode, curve, and voltage.
Allows finding dimmers based on multiple search criteria within the system.
Covers assigning dimmers to rooms and creating/managing presets.
Guides on configuring a personal computer for the ETCNet2 network connection.
Explains how to upload and install software updates to the CEM+ module.
Outlines the procedure for building a new system configuration from a NoConfig state.
Details setting and confirming network settings for CEM+ modules.
Explains how to set dimmer properties like firing mode, curve, voltage, and protection.
Describes how to assign dimmers or ranges of dimmers to specific rooms.
Differentiates between recording preset level information and snapshotting all available sources.
Explains configuration options for panic mode, including switch types and master level.
Covers downloading, uploading, and backing up configuration files via FTP.
Details the process of sending configuration or software files to the CEM+.
Provides information on how to contact ETC for technical support and services.
Explains how to easily replace dimmer modules and other components in Sensor+ racks.
Identifies the CEM+ fuses and provides instructions for replacing them.
Offers guidance on identifying and resolving system problems and errors.
Describes the truncated menu structure for touring and portable pack users.
Details features like synchronization and wall station control facilitated by SmartLink.
Explains how to synchronize presets and sequence activation across multiple devices.
Describes the available wall station types and their remote access capabilities.
Lists available station types, legends, and personality settings via dip switches.
Details the procedure for recording presets using a SmartLink wall station.
Explains the RTB system featuring two control modules per rack for automatic switching.
Describes IP addressing and rack numbering for RTB systems with dual CEM+ modules.
Provides step-by-step instructions for configuring an RTB system.
Details error messages displayed by the CEM+ and their probable causes and corrective actions.
Explains how to view error messages directly on the CEM+ LCD display.
Explains how dimmer curves determine voltage output in response to control signal input.
Describes the linear curve where control input percentage matches RMS voltage output.
Details a modified linear curve that reduces voltage change at low control levels.
Explains the square law curve that compensates for infrared loss at low control levels.
Describes a modified square law curve for more uniform response to control changes.
Mentions the Sensor 2.0 curve as a previous version for backwards compatibility.
Presents the entire face panel menu structure, indicating user access levels.
Outlines the structure and navigation of the Sensor+ Connect web interface.
Explains ACN as a standard for networked lighting control and ETC's Net3 protocol.
Details Sensor+ CEM+'s support for status reporting over Net3.
Lists potential configuration changes that can be performed remotely.
Explains how to use this manual and lists symbols used for warnings.
Lists changes and new features introduced in version 3.1 of the system.
Details the components that make up the Sensor+ system, including racks and modules.
Explains the function and configuration capabilities of the CEM+ control module.
Provides an overview of the web server interface for system configuration and monitoring.
Details features like playback of presets and feedback capabilities.
Explains how the CEM+ uses the ACN priority scheme to arbitrate input priorities.
Lists the maximum limits for racks, dimmers, presets, rooms, and other system parameters.
Describes the buttons and LCD display on the CEM+ face panel for navigation.
Covers basic operation, including login levels and main menu navigation.
Explains the NoConfig menu for initial base settings and configuration creation.
Provides status information about dimmers, racks, network, and group.
Details how to log in using user levels and PINs for system access.
Explains how to set dimmer firing mode, curve, scale, and preheat properties.
Describes how to enable/disable data ports and create the patch for input ports.
Defines how the system responds to DMX, EDMX, and sACN data loss.
Explains how to add additional racks to the existing system configuration.
Details how to activate, deactivate, record, and edit presets within rooms.
Covers activating, deactivating, recording, and clearing panic looks.
Explains how to record dimmer loads for Advanced Features systems.
Provides an overview of the web interface, its capabilities, and access methods.
Covers group management, including summary status and dimmer checks.
Allows access and setting of properties for all racks and dimmers in the configuration.
Details how to configure individual rack properties and settings.
Provides a single place to set all dimmer properties like mode, curve, and voltage.
Allows finding dimmers based on multiple search criteria within the system.
Covers assigning dimmers to rooms and creating/managing presets.
Guides on configuring a personal computer for the ETCNet2 network connection.
Explains how to upload and install software updates to the CEM+ module.
Outlines the procedure for building a new system configuration from a NoConfig state.
Details setting and confirming network settings for CEM+ modules.
Explains how to set dimmer properties like firing mode, curve, voltage, and protection.
Describes how to assign dimmers or ranges of dimmers to specific rooms.
Differentiates between recording preset level information and snapshotting all available sources.
Explains configuration options for panic mode, including switch types and master level.
Covers downloading, uploading, and backing up configuration files via FTP.
Details the process of sending configuration or software files to the CEM+.
Provides information on how to contact ETC for technical support and services.
Explains how to easily replace dimmer modules and other components in Sensor+ racks.
Identifies the CEM+ fuses and provides instructions for replacing them.
Offers guidance on identifying and resolving system problems and errors.
Describes the truncated menu structure for touring and portable pack users.
Details features like synchronization and wall station control facilitated by SmartLink.
Explains how to synchronize presets and sequence activation across multiple devices.
Describes the available wall station types and their remote access capabilities.
Lists available station types, legends, and personality settings via dip switches.
Details the procedure for recording presets using a SmartLink wall station.
Explains the RTB system featuring two control modules per rack for automatic switching.
Describes IP addressing and rack numbering for RTB systems with dual CEM+ modules.
Provides step-by-step instructions for configuring an RTB system.
Details error messages displayed by the CEM+ and their probable causes and corrective actions.
Explains how to view error messages directly on the CEM+ LCD display.
Explains how dimmer curves determine voltage output in response to control signal input.
Describes the linear curve where control input percentage matches RMS voltage output.
Details a modified linear curve that reduces voltage change at low control levels.
Explains the square law curve that compensates for infrared loss at low control levels.
Describes a modified square law curve for more uniform response to control changes.
Mentions the Sensor 2.0 curve as a previous version for backwards compatibility.
Presents the entire face panel menu structure, indicating user access levels.
Outlines the structure and navigation of the Sensor+ Connect web interface.
Explains ACN as a standard for networked lighting control and ETC's Net3 protocol.
Details Sensor+ CEM+'s support for status reporting over Net3.
Lists potential configuration changes that can be performed remotely.
| Brand | ETC |
|---|---|
| Model | sensor+ CEM+ |
| Category | Control Systems |
| Language | English |