Basic Navigation 19
Edit Name [Power]
The Edit Name menu allows you to update the name of a recorded preset. Names are alphanumeric
and can be up to 20 characters long (not all 20 characters will be visible on the LCD).
Power Up Behavior [Power]
The Power Up Behavior menu allows you to specify how all of the racks in the group behave upon
booting up. Normal mode does not retain any active presets or dimmer levels. Previous mode will
reactivate any presets that were active prior to the unit losing power or rebooting.
Station Master [Power]
The Station Master menu allows you to enable or disable this CEM+ as the Station Master. It is
important to understand that an entire Sensor+ group of racks acts (and counts) as a single device on
the SmartLink network. The
Station Master
is the
Host Product
for SmartLink preset playback and
synchronization. See
SmartLink Stations Enabled
on
page 63
for more information.
Remote Record [Power]
The Remote Record Menu allows you to enable or disable the ability to record presets from SmartLink
Stations over the network. Once it is enabled, it remains enabled until you turn it off again. See
Record
a Preset from a Wall Station
on
page 68
for more information.
Edit Room Name [Power]
The Edit Room Name menu allows you to set the name of a room.
Max Active Presets [Power]
The Max Active Presets menu allows a you to set the maximum number of active presets for a selected
room.
DMX Loss Presets [Power]
The DMX Loss Presets menu allows you to set the preset that is made active upon DMX data loss on
DMX Port A or Port B for each room that has a preset recorded for it.
Panic [User][Power]
The Panic menu allows a User to activate and deactivate the Panic look and allows a Power User to
record and clear the Panic look.
Activate Panic
The Activate Panic menu toggles between “Activate” and “Deactivate”, depending on the status of
the Panic look.
Record Panic [Power]
The Record Panic menu allows you to record dimmers that currently have an output level at the Master
Level, or greater, to the Panic look. You can set the Master Level to anything between 80% and 100%.
When the Panic look is activated, the assigned dimmers will all output at the Master Level. You can also
choose to set all other dimmers to turn off when panic is activated.
Delete Panic [Power]
The Delete Panic menu allows you to clear the current Panic settings.
Hold Time [Power]
The Hold Time menu allows you to set the panic hold time to 0 to 30 seconds.
Configure Switches [Power]
The Configure Switches menu allows you to define the external switch action types (maintained vs.
momentary) and resting states (normally-open vs. normally-closed).