Basic/Portable Mode 61
Appendix A
Basic/Portable Mode
Basic/Portable mode is a separate mode that you can put the CEM+ into when you initially begin the
configuration. It is a truncated menu structure focusing on the functions that touring rack and portable
pack users need most often allowing for quicker navigation and ease of configuration. To switch
between Basic/Portable Mode and Full Feature Mode, you need to start over with your configuration as
this choice can only be made while generating the default state of a CEM+.
This mode also brings some notable limitations with its simplicity of use. See the list below for general
features and limitations:
Each dimmer can be modified to operate in “switched” or “normal” dimming modes.
Face panel menu allows you to set the incoming power type to either single phase or three phase
power, depending on your physical incoming power setup.
If Dimmer Doubling is selected, the whole rack is dimmer doubled.
AF modules are able to be selected. However, AF functions are not enabled, such as: Load
recording, Load errors and so on.
Patch mode is limited to a starting address and numbers the dimmers contiguously within the
rack.
Basic/Portable mode is limited to DMX input port A and DMX B at the same start address only.
DMX B will pile on to DMX A if both are present.
Basic/Portable mode turns off the web interface of the CEM+. All configuration is done via the
face panel.
Panic and Preset functionality is turned off.
EDMX and sACN are disabled.
Basic/Portable is intentionally limited in functionality for ease of use. If features are required that are
not available in this mode, Full Feature mode should be used.