68 Sensor+ CEM+ User/Config Manual
Record a Preset from a Wall Station
It is possible to record a preset from a wall station if “Remote Record” has been enabled in the station
master. See
Remote Record [Power]
on
page 19
. All products on the SmartLink network will record the
current output levels and assign the preset to the button.
1. Set dimmer levels to a desired look via the test menu and/or other DMX control device.
2. Press and Hold the preset button for 5 seconds.
After two seconds, the LED will start to blink at a 1/2 second interval. If the button is held
for 5 seconds a record action will be begin.
If the button is released before the 5 seconds have elapsed, recording will be canceled and
the normal preset will be activated.
3. Release the preset button. The new recorded preset will activate and the LED will illuminate.