Operation & Software Manual
282
Direct Drives & Systems
Chapter E: Appendixes ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
DSC2P and DSC2V parameters
4
Trigger at a register value defined by K127. K126=0
means that register defined in depth 0 is chosen for
trigger, and K126=1 for depth 1,…
5
Trigger never starts; only ZFT command can start trigger
acquisition
K126
The value indicates that the register selected for the
trigger condition is defined in depth of K121 and K122
parameters. See EBL2 manual
003
K127
Value of the register selected by K121, K122 and K126
parameters for acquisition start. See EBL2 manual
0 -2147483648 2147483647
K128 Number of points for the trace. See EBL2 manual 1024 0 1024
K133 AUT command definition mode 0 0 1
0
Principle for finding the fine phase adjustment 0:old
principle 1:new principle
K135 Optional board parameter (see optional board manual) 0 -2147483648 2147483647
K136 Optional board parameter (see optional board manual) 0 -2147483648 2147483647
K137 Optional board parameter (see optional board manual) 0 -2147483648 2147483647
K138 Optional board parameter (see optional board manual) 0 -2147483648 2147483647
K139 Optional board parameter (see optional board manual) 0 -2147483648 2147483647
K140 Mask for fuse control 0 0 1
1 0 Disables test of F3 fuse (from DSC2Pxxx-xxxC-xxxx)
K141
Enables test of motor overtemperature protection
connected to TSD signal (see Hardware Manual), and/or
time-out TEB error, and/or enables the checking of the
error for the secondary encoder
007
10
Enables test of motor overtemperature protection
connected to TSD signal (see Hardware Manual)
2 1 Enables time-out TEB error test
42
Enables the checking of the error for the secondary
encoder
K145 Searches limit stroke (SLS) mode 0 0 3
0 Positive movement to search mechanical end stop
1 Negative movement to search mechanical end stop
2 Positive movement to search mechanical limit switch
3 Negative movement to search mechanical limit switch
K146
Limit of Vpower to activate undervoltage warning [V/
100]. When Vpower[V] * 100 is lower than K146, the
controller generates an undervoltage warning (M66=10).
If K146=0, the limit detection is disabled
0 0 100000
K147
Limit of Vpower to activate undervoltage error [V/100].
When Vpower[V] * 100 is lower than K147, the controller
generates an undervoltage error (M64=9). If K147=0,
the limit detection is disabled
0 0 100000
K148
Limit of Vpower to activate overvoltage warning [V/100].
When Vpower[V] * 100 is greater than K148, the
controller generates an overvoltage warning (Set bit#19
of SD1). If K148=0, the limit detection is disabled. For
DSC2P the limit is reduced by firmware
70000 0 100000
K149
Limitt of Vpower to activate overvoltage error [V/100].
When Vpower[V] * 100 is greater than K149, the
controller generates an overvoltage error (M64=6). If
K149=0, the limit detection is disabled. For DSC2P the
limit is reduced by firmware
80000 0 100000
K Alias
Val
<P1>
Bit #
<P1>
Comment for parameters K
and <P1> of the DSC2P and DSC2V
Def. Val
<P1>
Min. Val
<P1>
Max. Val
<P1>