144 WT.050.570.000.DE.IM.0714
Installation / Commissioning DEPOLOX
®
Pool
2.7
Switching
the mains voltage over
To switch the mains voltage over from 230 V AC to 115 V AC:
1. Disconnect the device from the power supply.
2. Remove the cover of the electronic module
3. Remove the relay card (1, Bild 43).
4. Through the empty slot of the relay card (1) switch the mains
switch on the motherboard (for example with a screwdriver).
NOTE
It is not necessary to replace the fuses.
5. Reassemble the device.
Fig. 43 Switching the mains switch over
2.7.6 Mounting the Labelling Field
1. Select the supplied labelling field in accordance with the specified
configuration.
2. If necessary supplement the labelling field.
3. Insert the labelling field for the LEDs on the inside of the housing
cover of the electronic module in accordance with the selected ap-
plication.