EasyManua.ls Logo

Evoqua DEPOLOX - Mounting the Labelling Field; Switching the Mains Voltage over

Evoqua DEPOLOX
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
144 WT.050.570.000.DE.IM.0714
Installation / Commissioning DEPOLOX
®
Pool
2.7
Switching
the mains voltage over
To switch the mains voltage over from 230 V AC to 115 V AC:
1. Disconnect the device from the power supply.
2. Remove the cover of the electronic module
3. Remove the relay card (1, Bild 43).
4. Through the empty slot of the relay card (1) switch the mains
switch on the motherboard (for example with a screwdriver).
NOTE
It is not necessary to replace the fuses.
5. Reassemble the device.
Fig. 43 Switching the mains switch over
2.7.6 Mounting the Labelling Field
1. Select the supplied labelling field in accordance with the specified
configuration.
2. If necessary supplement the labelling field.
3. Insert the labelling field for the LEDs on the inside of the housing
cover of the electronic module in accordance with the selected ap-
plication.
1
W&T00069

Table of Contents

Related product manuals