134 WT.050.570.000.DE.IM.0714
Installation / Commissioning DEPOLOX
®
Pool
2.7
2.7.1 Filling Cell Sand
CAUTION!
Before opening the cover on the pressurised version always first re-
lease the pressure in the cell body with the drain screw.
1. Remove the cover from the cell body:
On the non-pressurised version lift the cover.
On the pressurised version unscrew the cover.
2. Fill half a screw cap of "cell sand" (W3T171317) into the cell body,
also refer to the section "Maintenance".
3. Refit the cover onto the cell body.
On the non-pressurised version align the catch on the cover
and snap the cover into place.
On the pressurised version screw the cover into place. The
correct position is reached at the end of the thread.
Sensor
arrangement