Pool Installation
WT.050.570.000.DE.IM.0714 97
2.4
2.4 Installation
Installation site The device must be protected against rain, frost and direct sunlight and
may therefore not be installed outdoors.
It must be mounted horizontally on a flat wall in a frost-free room with
an ambient temperature of 0 to 50 °C.
The air in the room should be non-condensing.
Opening the housing 1. Remove the housing cover of the flow block assembly. To this pur-
pose press the two buttons on the top of the housing.
2. Release the five screws on the cover of the electronic module.
CAUTION!
The indication and operating elements on the cover of the electronic
module are connected to the housing with wires.
NOTE
The device switches off automatically when the cover is removed.
3. Carefully remove the cover of the electronic module and leave to
hang on the strain relief.
Closing the housing 1. Tighten the housing screws with max. 0,7 Nm (±0,15 Nm).