DEPOLOX
®
Pool Technical Data
WT.050.570.000.DE.IM.0714 89
2.2
2.2 Technical Data
2.2.1 Electronic module
Housing Dimensions (W x H x D): 320 x 270 x 175 mm
Weight: approx. 5 kg
Protection category: IP 67
Platform Mains connection
200 ... 240 V AC ± 10 %, 50-60 Hz, 30 VA, fuse 1A (T) type: TR5
100-120 V AC ± 10 %, 50-60 Hz, 30 VA, fuse 1A (T) type: TR5
24 V DC ± 20 %, 30 W, fuse 2.5 A (T) type: TR5
Insulation
Overvoltage category 2
Contamination level 2
Operating conditions
Ambient temperature 0 ... 50 °C
Environment No direct sunlight
Atmospheric pressure 75 ... 106 kPa
max. altitude 2000 m
Relative humidity <80%, not condensing
Storage temperature -20 ... +70 °C
Noise emission < 45 dB
Digital inputs 3 x for floating contact (< 100 Ohm)
Power supply through DEPOLOX
®
Pool
D1: Sample water monitoring
D2: Freely selectable in menu
D3: Freely selectable in menu
input open: digital input activ
input closed digital input not activ
Measurement inputs 1 x Temperature input PT 1000 (0 ... 50 °C) with sensor error display
1 x Feedback input
Positioner position feedback
Potentiometer 1 kOhm
5 x Measurement value input
Direct plug connector for plug-in cards of the sensor measuring
module
Free chlorine
Total chlorine
pH value
Redox potential
Conductivity