DEPOLOX
®
Pool Description
WT.050.570.000.DE.IM.0714 19
1.2.3 Function
Overall function Up to seven measured values can be indicated by specific process
components:
Free chlorine*
Combined chlorine*/Total chlorine*
pH value*
Redox potential
Conductivity*
Temperature
The value of the combined chlorine is calculated from the difference
between the total chlorine and the free chlorine.
The graphic display shows the measured data, limit values and set-
points as numeric values, diagrams or a trend line.
All measured values can be displayed at the same time. The pre-set li-
mit values meet the requirements of DIN 19643 "Treatment of water of
swimming-pools and baths".
Flow block assembly The flow block assembly guarantees a stable measurement signal with
Robust sensors
Constant sample water flow rate with the aid of the flow control val-
ve
Hydrodynamic sand cleaning of the chlorine sensor measuring
electrodes
Optimum flow around all sensors
The multi-sensor integrated into the flow block assembly monitors the
constant sample water flow rate, registers the sample water tempera-
ture and ensures wide-spread equipotential grounding (sample water
grounding).