EasyManua.ls Logo

Extron electronics DMP 128 Plus - Page 146

Extron electronics DMP 128 Plus
187 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DMP 128 Plus • Remote Control and Configuration 138
NOTES:
X5%
= Digital Output 1 or 2
X5^
= Output Mode 0 = Output always high
1 = Output always low
Mutes
2 = Mute high
3 = Unmute high
Group Mutes
4 = Group mute high
5 = Group unmute high
Macros
6 = Macro started set high once (blink)
7 = Macro started set low once (blink)
Presets
8 = Preset recalled set high once (blink)
9 = Preset recalled set low once (blink)
Automix Gate Status
10 = Automix gate on (>1024) set high
11 = Automix gate on (>1024) set low
Signal Presence
12 = Signal presence (>-40dBFS) set high
13 = Signal presence (>-40dBFS) set low
X5&
= Varies according to output
mode
Mutes
Input number for monitoring. If X5^ is not specified, monitoring
defaults to the input with the corresponding I/O channel number.
Group Mutes
Group member for mute monitoring. If X5^ is not specified, muting
matches the group with the corresponding I/O channel number.
Macros
Macro number. If X5^ is not specified, the macro number defaults
to the corresponding I/O channel number.
Presets
Preset number. If X5^ is not provided, the preset number defaults
to the corresponding I/O channel number.
Automix Gate Status
Input number for automix gate monitoring. If X5^ is not speci-
fied, the input number defaults to the corresponding I/O channel
number.
Signal Presence
Input Number for signal presence monitoring. If X5^ is not speci-
fied, the input number defaults to the corresponding I/O channel
number.

Table of Contents