A1400 AIR RDT 75 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
16 Alerts
Indication Intervention required
41
Date and time loss Reset time and date with SDK EVO.
42
Clock battery flat or absent In case of mains power supply failure, replace the battery to avoid losing the time.
43
System test System test in progress
44
Emergency active signal that an emergency is active
45
Timer active the TIMER is in activated state
46
Timer Function in progress A TIMER function is running with operating mode other than
Total Two-directional Automatic)
47
Last motion run with battery The board has run the last motion programmed.
48
Night-time mode operation Night-time mode operation.
49
Manual mode operation Manual mode operation
50
Partial mode operation Partial mode operation
51
Obstacle in closure detected The door opens again. Check for an obstacle in closing
52
Obstacle in opening detected After 5 sec. the door attempts another opening.
Check for an obstacle in opening.
53
Number of maintenance cycles corrupted on E
2
prom Replace the control board and perform maintenance on the system.
54
Fault on Motor_1 block driver Perform RESET. Check the motor block
55
Operation in pharmacy mode in progress PHARMACY opening is in progress.
56
Battery operation the indication remains as long as the automation operates on battery with mains power
supply down.
57
Searching for strike on opening the indication remains as long as the stage is ongoing
58
Searching for strike on closing the indication remains as long as the stage is ongoing
59
Motor block Anomaly (only with Monitoring Kit) Perform RESET. If the problem persists replace the motor block.
60
Maintenance requested
(with acoustic signal at 4 s intervals).
3 s
Have scheduled maintenance performed and reset the relevant cycle counter with SDK EVO.
61
Fault SDK EVO o LKEVO Check it is the correct device and check the connections SDK EVO or LKEVO.
Update FW (see procedure 78).If the problem persists, replace SDK EVO or LKEVO.
62
Faulty battery charger Perform RESET. If the problem persists replace the control board.
63
Intrusion in progress An attempt to manually open the leaves is in progress
64
Last opening too slow, not compliant with EN16005
after 10 openings with this alert active, the system goes into error
21
65
SETUP in progress SETUP is in progress.
66
The AUX board is moving the leaves Opening with AUX board is in progress.
67
Battery saving Power supply to the accessories of the board (Excluding SDK EVO or LKEVO) has been discon-
nected to save and avoid quick discharge of the battery.
68
Alarm on Test Check detector operation. If the problem persists, replace the detector.
In this condition the leaves move at a slower speed.
69
Door open the door is open for semi-automatic OPEN function.
70
Low batteries level batteries charging
80
Programming other than standard Alert not displayed by the board.
* When the condition is restored, this error disappears without requiring a RESET.
17 AUX Errors
AUX Errors Intervention required
200
UC Failure (Corrupted FW or Corrupted RAM) Carry out board reset; if the error persists replace the board.