16 2011 ACCESS CONTROL
2011 ACCESS CONTROL 17
16 2011 ACCESS CONTROL
2011 ACCESS CONTROL 17
City Classic Private
Ref.2347
Proximity
• Access control reader which allows the door to be opened
by swiping the proximity card or keyring . Only authorised
cards or keyrings activate the device. Physical contact is
not necessary.
• Capacity: up to 400 user cards or keyrings.
• Integrated within the City Classic aluminum panel.
Flush mounted (ref.8948, including box) or surface
installation (ref.8951, optional).
• Recommended for interior and exterior use.
• Reader and controller integrated within the same module.
Acoustic and visual confirmation using LEDs which
advise if the card presented has been accepted/rejected.
Dimensions: (horizontal)x(vertical)x(depth) mm
INSTALLATION
TECHNICAL FEATURES
Does not require physical contact.
3cm (card) or 1cm (keyring) reading distance.
Acoustic and visual status data.
Manual programming (using master card or keyring)
or via PC software (card activation/deactivation).
Door sensor and exit button control.
Relay output.
Relay lock-release activation with programmable time.
Programmable from 1 to 99 seconds.
Status LEDs (help in programming and determining
status).
SPECIFICATIONS
• Dimensions:
* Reader
* Flush Mounted Box
* Surface Box
• Environmental Protection (IP)
• Anti-Shock Protection (IK)
• Power Supply (V)
• Consumption (mA) S/lock-release
• Operating Temperature
130x128
115x114x45
130x128x33
43
07
12V (ac/dc)
80/120
0º to 60ºC
The reader is located in the exterior area. The rest of the
devices are connected to this module and they are installed in
the building's interior: power supply and lock-release. An exit
button can be used optionally.
Lock-Releases
Exit Button
Power Supply
Ref.2347
230Vac
2
2
2
2
PROGRAMMING
This can be done in 3 ways:
Master card: The first time the power supply is
connected, the system waits for a proximity card to be
swiped. This is then considered the "master card".
Keypad: Recommended if we want to deactivate
faulty cards.
PC Software: For managing user activation/
deactivations.
The WINPROX software can be downloaded from
www.fermax.com
IDENTIFIERS
1. Card without magnetic strip (ref.23361); 2. Card with magnetic strip
(ref.2336); 3. Proximity keyring (ref.44501).
1 2
3
STAND-ALONE
12Vdc
12Vac
30708
3071
2888
2880
* Door lock recommended.