40 2011 ACCESS CONTROL
2011 ACCESS CONTROL 41
40 2011 ACCESS CONTROL
2011 ACCESS CONTROL 41
CAC Central Unit
Ref.4410
PROGRAMMING
• 2.048 users.
• 32 access points.
• Continual access testing.
• Register of the last 3.000 incidents (entries, exits,
access denied, alerts, etc.) within the memory
without the need to download it to the PC.
• Option to connect readers with or without an
integrated controller (via the door controller).
All programming is done using the CAC software and
from a duly authorised computer. CAC software is
included on the Central Unit in CD format or can be
downloaded from www.fermax.com
System centralisation involves a central unit, a power
supply and relevant PC connection devices. We
recommend to use an emergency power supply
system (battery).
In systems with large distances, you will need to install
additional power supplies at the access points in order
to avoid drops in voltage with wiring.
Installation is done using 2 wire BUS and a shielded
twisted pair. Interconnection of various central units
requires a further wire.
INSTALLATION
Dimensions: (horizontal)x(vertical)x(depth) mm
• Dimensions
• DIN rail xed in place or 2 screws to wall
• Surface Box (optional)
• Power Supply (V)
• Consumption (mA) S/lock-release
• Operating Temperature
175x90x40
130x128x33
12Vdc
150
0º to 60ºC
SPECIFICATIONS
TECHNICAL FEATURES
• Central Unit for large access control systems. Manages up to
32 access points or doors with a total of 2.048 users.
• Allows the installation of 1 MDS Digital Guard Unit (just one
throughout the entire system).
• A maximum of 64 Central Units can be connected
(2.048 access points).
• Incorporates the CAC management software in CD format.
This software is comprised of various applications: "Server
Applications" and "Client Applications".
- Server Applications: developed for the installer.
· CAC Database Server: this is the application that manages
the database which stores all the information and which
transmits all data to the rest of the user applications and to the
CAC Server.
· CAC Server: this is the application where the installer defines
the system's hardware elements (central unit, readers, decoders,
etc).
All CAC systems have one unique CAC Server and CAC
Database Server.
· Client Applications: developed for the user via a simple,
intuitive, graphic interface. Multi-Station Applications.
· CAC Access: User and Authorisation Management event
viewing, etc.
· CAC Attendance: Presence Control Management (compilation
of employee payslips). Allows you to capture, define and control
the hours worked by employees within a company using the
same access control readers.
• Ability to manage 1.000 intercommunication panels, 1.000
sensors and 1.000 relays.
• Local Connection (USB, RS-232) or remote connection (IP) to the
corresponding module (see accessories).
Reader
Reader Reader
Up to 32 readers
Up to 32 readers
2
3
2
3
2
2
Twisted Pair
Twisted
pair
twisted
pair
Up to 64 Central Units
C.U.
(ref.4410)
C.U.
(ref.4410)
C.U.
(ref.4410)
Twisted Pair
Power Supply
Twisted Pair
2
2
Up to 32 readers
CENTRALISED