Door Sensor / Relay
Proximity readers
desktop
Power Disconnector
REF. 1076 MAGNETIC CONTACT
Surface system between door and door frame. Connected to
the controller's door sensor input.
REF. 3491 DIN RELAY 12Vdc/12A
Makes it possible to activate a device up to 12A.
REF. 2349 DESKTOP PROXIMITY READER
Allows in MDS system to activate proximity identiers
easily and rapidly in the PC using the management software.
PC Connection: RS-232. Cable included.
230Vac power supply using adaptor (included).
REF. 4475 ENERGY DISCONNECTOR
Allows the electrical current to be disconnected from the devices
in a room when the user is not in it. To disconnect the user must
enter their proximity card in the disconnector (only works with
proximity cards). The card must be removed from the disconnector
once the user leaves the room. He will have 10 courtesy seconds
with the light on to leave the room.
It is designed to be used additional to stand-alone or centralised
proximity readers as it uses the same cards. The user is obliged
to remove the card from the disconnector to be able to re-open
the door to the room.
Flush mounted installation using 60x70mm boxes.
230V Operation. Circuit Power: 6,000W.
Proximity Technology: EM, TEMIC, RF256 and TK cards.
3
RS-232
ref.2349
230Vac
ACCESSORIES
Pc