FIMER_PVS-175-TL A.1 Version_Product manual_EN_RevC-
F
165
Problem Possible causes Solution
It is not possible to
access the Web User
Interface using the IP
address when the
inverter is operating in
“Station Mode – DHCP.
An incorrect dynamic IP
address is being used to
access the Web User
Interface or the IP address
could have been modified by
the wireless router to which
the inverter is connected.
The IP Address used to
access the Web User
Interface was lost.
Access the Web User Interface using via “AP
Mode” (refer to Access to the Web User
Interface” paragraph to know how to connect
via “AP Mode”) and read the current IP
Address in “CONNECTIVITY > WLAN
section (“CONNECTIVITY menu”).
Access the Web User Interface using the
“Host Name” that could be obtained writing
this url http://ABB-XX-XX-XX-XX-XX-XX.local
replacing the “X” with the hex digits of the
MAC address of the inverter (it can be found
on the “Communication Identification Label”
placed on the side of the inverter or applied
during the commissioning phase to the plant
documentation). The DNS or multicast
service must be enabled on router.
Note: This connection method doesn’t work
on Android devices.
If possible, access the pages of the wireless
router web server to which the inverter is
connected and read the new dynamic IP
address assigned to the Inverter.
The wireless router doesn’t
allow the connection to local
IP address. Tipically this
happen on company
networks.
Contact the network administrator to allow
the wireless router to connect to local IP
address.
The device doesn’t allow the
connection to local IP
address. Tipically this happen
with company devices.
Contact the system administrator to allow the
device to connect to local IP address.
Using an Android
devices, a notification
advise that internet
connection is missing
when trying to connect
to the Access Point
wireless network
created by the inverter
and ask for connection
confirmation.
Known behavior of Android
devices. Android OS always
check if internet connection
are available and ask for
confirmation if its not
present.
Confirm the connection request in the
notification of Android devices by clicking
Yes.

Table of Contents