62 PF7/PF7+ Peristaltic Filler with QC14 Pumphead User Manual
20.16 Weigh check frequency
i
Zero waste filling only. Refer to "Start Zero waste batch"
on page 91.
Requires a connected balance.
During a manual batch, frequency of weigh checking is
determined by the operator. Refer to "Weigh check option"
on page 113.
How often the fill is weight checked using the connected balance, refer to "Zero
waste filling - weigh checked fill" on page 95.
Set to 1 to weigh check every fill.
The fills in between the checked fills are non-checked. Refer to "Zero waste filling -
non weigh checked fill" on page 97
When the fill is weight is checked:
the result is stored in the batch report
the pump is recalibrated
the fill will take longer than a non-checked fill due to the stabilisation of the
balance reading
Table 11 - Example weigh check frequencies
Weigh
check
frequency
Fill number
1 2 3 4 5 6 7 8 9 10
1
2
3
= Checked fill