3.4 Programming Mode
3-39
Chapter 3
KEYPAD FUNCTIONS
LED
monitor
Item Description
5_36
Light alarm factor
(Latest)
Shows the factor of the latest light alarm as an alarm code.
For details, refer to the description of H81 in Chapter 5.
5_37
Light alarm factor
(Last)
Shows the factor of the last light alarm as an alarm code.
For details, refer to the description of H81 in Chapter 5.
5_38
Light alarm factor
(2nd last)
Shows the factor of the 2nd last light alarm as an alarm code.
For details, refer to the description of H81 in Chapter 5.
5_39
Light alarm factor
(3rd last)
Shows the factor of the 3rd last light alarm as an alarm code.
For details, refer to the description of H81 in Chapter 5.
5_40
Option error factor 1
Shows the factor of the error that has occurred in the option being
connected to the A-port.
5_41
Number of option
errors 2
Shows the total number of errors that have occurred in the option being
connected to the B-port.
Once the count exceeds 9999, the counter will be reset to "0."
5_42
Option error factor 2
Shows the factor of the error that has occurred in the option being
connected to the B-port.
5_43
Number of option
errors 3
Shows the total number of errors that have occurred in the option being
connected to the C-port.
Once the count exceeds 9999, the counter will be reset to "0."
5_44
Option error factor 3
Shows the factor of the error that has occurred in the option being
connected to the C-port.