5.3 Code Index by Purpose
5-58
To:
Function
code
Name
Refer to
page:
y02
y03
y08
RS-485 Communication 1
(Communications error
processing)
(Timer)
(No-response error detection
time)
Communications
error
Detect a communications error.
y12
y13
y18
RS-485 Communication 2
(Communications error
processing)
(Timer)
(No-response error detection
time)
5-272
PID feedback
wire break
Stop the system if a PID feedback wire breaks
(current input on [C1]).
H91
PID Feedback Wire Break
Detection
5-207
Excessive speed
deviation
Detect that a deviation between the reference
speed and detected one is out of the specified
range.
d21
d22
d23
E20 to E24
Speed Agreement/PG Error
(Detection width)
(Detection timer)
PG Error Processing
Terminal [Y1] to [Y5A/C]
Functions (PG-ERR)
5-241
5-141
Detect a PG error such as a PG wire break.
d21
d22
E20 to E24
Speed Agreement/PG Error
(Detection width)
(Detection timer)
Terminal [Y1] to [Y5A/C]
Functions (PG-ERR)
5-241
5-141
PG wire break
Ignore a PG wire break alarm. E01 to E09
Terminal [X1] to [X9] Functions
(PG-CCL)
5-122
Force to stop Use the forced stop function for safety.
H56
E01 to E09
Deceleration Time for Forced
Stop
Terminal [X1] to [X9] Functions
(STOP)
Terminal [X1] to [X9] Functions
(STOP-T)
5-76
5-122
Coast to a stop Use the coast-to-stop function for safety. E01 to E09
Terminal [X1] to [X9] Functions
(BX)
5-122
STOP key
priority
Always enable the STOP key for safety. H96
STOP key priority/Start check
function
5-202
Start check
function
Check in specified situation changes whether
any run command has been turned ON for
safety. This is to prevent the motor from running
suddenly.
H96
STOP key priority/Start check
function
5-202
Heat sink
overheat early
warning
Issue a heat sink overheat early warning before
an overheat trip actually happens.
E20 to E24
Terminal [Y1] to [Y5A/C]
Functions (OH)
5-141
Cancel of current
limit processing
Cancel the current limit processing if invoking it
drops the motor toque temporarily, causing a
problem.
H12
Instantaneous Overcurrent
Limiting (Mode selection)
5-117
Clear alarm history and relevant information
stored in the inverter.
E01 to E09
H97
E20 to E24
Terminal [X1] to [X9] Functions
Clear Alarm Data Terminal [Y1] to
[Y5A/C] Functions
5-122
5-208
5-141
Alarm
Cause the inverter to generate a mock alarm. H45 Mock alarm 5-197