l Integrity - Checks the integrity of data in the blockpool. This healthcheck examines a
sample of data tags in the blockpool and verifies that the data has been properly stored
without errors or corruption.
To access the Status page, on the Healthchecks page, click the Status tab (see "Status
Page" on page 445).
Figure 285: Status Page
The Status page displays the following information about the most recently run test for each
healthcheck:
Healthcheck Name The name of the healthcheck.
State The state of the healthcheck (enabled or disabled).
Started The time the healthcheck started
Finished The time the healthcheck ended.
Status The status of the healthcheck (Success or Failed).
If running a healthcheck results in the Contact Support
status, contact Fujitsu Technology Solutions Customer
Support for further assistance.
To enable or disable a healthcheck:
1. Select the healthcheck and click Edit.
The Edit Healthcheck page displays (see "Edit Healthcheck Page" on page 446).