TX100 S3 Upgrade and Maintenance Manual 163
Expansion cards and backup units
Ê Reconnect all external cables to the replaced expansion card.
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section "Connecting the server to the mains" on
page 59.
Ê Enable the PCI slot of the replaced expansion card as described in section
"Enabling replaced components in the system BIOS" on page 78.
Ê Inform the customer about changed WWN and MAC addresses. For further
information, refer to section "Looking up changed MAC / WWN addresses"
on page 83.
Ê After replacing a network controller in a server running Linux OS, "Updating
the NIC configuration file in a Linux environment" on page 80.
Ê If applicable, reconfigure your network settings in the operation system
according to the original configuration of the replaced controller (expansion
card or onboard).
The following notes are required for TX100 S3p (PYT10Pxxx for Japanese
market).
I Configuration of network settings should be performed by the
customer.
For further information, please refer to section "Note on network
settings recovery" on page 161.
Ê After installing or replacing a Modular RAID controller, update the firmware
as described in section "Updating RAID controller firmware" on page 75.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 82.
Ê If applicable, restore LAN teaming configurations as described in section
"After replacing / upgrading LAN controllers" on page 85.

Table of Contents