TX100 S3 Upgrade and Maintenance Manual 319
System board and components
Ê Install the HDD cage as described in section "Installing the HDD cage" on
page 63.
Ê Close the side cover as described in section "Installing the side cover" on
page 58.
Ê Reconnect all external cables.
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section "Connecting the server to the mains" on
page 59.
Ê If available, update the system board BIOS to the latest version as described
in section "Updating the system board BIOS" on page 73.
Ê Verify and update time settings as described in section "Verifying the system
time settings" on page 78.
Ê Restore the BIOS settings manually.
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
"D3009 BIOS Setup Utility for PRIMERGY TX100 S3 Reference Manual".
Ê Inform the customer about changed WWN and MAC addresses. For further
information, refer to section "Looking up changed MAC / WWN addresses"
on page 83.
Ê After replacing the system board in a server running Linux OS, update the
MAC address of the onboard network controller in the related NIC definition
file as described in section "Updating the NIC configuration file in a Linux
environment" on page 80.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 82.
Ê If applicable, reconfigure your network settings in the operation system
according to the original configuration of the replaced controller (expansion
card or onboard).
The following notes are required for TX100 S3p (PYT10Pxxx for Japanese
market).
I Configuration of network settings should be performed by the
customer.
For further information, please refer to section "Note on network
settings recovery" on page 304.