ASSEMBLING
CAUTION: the homogenizing assembly is normally subject to high
pressure and temperature conditions which impose a considerable stress
on the seal gaskets.
To ensure a correct operation and avoid product leakage or product
contamination, it is recommended to replace all gaskets every time that
the homogenizing group is disassembled.
CAUTION: to facilitate the gasket assembling, grease them with food-
grade Vaseline or similar.
FIGURA 4.5.3
− Put the homogenizing valve chamber (B) on its side and insert the impact
head guide (T)
− Put inside the impact head (G) and make sure this is not coming out of its
guide (T)
− Assemble the impact ring (U)
− Put the homogenizing valve chamber on the studs and push it towards the
compression head
− Assemble the impact ring (U) and the passage head (V) inside the housing
(D), including the Orings (E, F), then put all the parts inside the valve
chamber (B)
4c053e0c.doc 4.5.5