during the final machine test so we recommend you do not change these
settings.
FIGURE 4.11.1
These valves (N) can be used to adjust the backpressure inside the exchanger
(E), measured by the pressure gauge (K); to ensure proper operation of the
exchanger it should be set to 1÷2 bar.
Valves (C) are used to adjust the flow of cooling water so that the temperature
of the condensate flow is approximately 40÷60 °C.
ASEPTIC CHAMBERS
The aseptic chambers of the plungers only require replacement of the gaskets.
To avoid contamination, make sure you accurately clean and sterilize the
aseptic chambers whenever there are product leaks from the packings.
4c111e0c.doc 4.11.2