Niro Soavi S.p.A
PERIODICAL MAINTENANCE TABLE – GENERIC FOR ALL MACHINES
When Action required Machine hrs
After first start-
up
Check belt tensioning
replace lubrication oil
replace lubrication filter
200
500
500
Every day check oil level and top up and if needed
visual check for leaks in seals and gaskets
Once a week -
40 hrs
visual check of plunger gaskets
drain condensate from lubrication system
check tightening of nuts and plungers
check drive
check belt tensioning
check tightening of drive elements and
reducer support
When
(hrs)
Action required Mach.
hrs
Operator Date
1500 and
every
1500 hrs
change lubrication oil
clean/replace filters (lubrication
system, pneumatic system, water
system)
check drive belt wear, tensioning
and if required replace
check wear of plungers and if
required replace
check pressurization of pneumatic
system and oil level
check oil level in gear reducer
3000 and
every
3000 hrs
check / replace springs and
pumping valves
check / replace homogenizing
valve
every
5000 hrs
replace lubrication oil in gear
reducer (mineral oil)
4c010e0c.doc 4.2.2

Table of Contents