PERIODICAL MAINTENANCE TABLE – GENERIC FOR ALL MACHINES
When Action required Machine hrs
After first start-
up
• Check belt tensioning
• replace lubrication oil
• replace lubrication filter
200
500
500
Every day • check oil level and top up and if needed
• visual check for leaks in seals and gaskets
Once a week -
40 hrs
• visual check of plunger gaskets
• drain condensate from lubrication system
• check tightening of nuts and plungers
• check drive
• check belt tensioning
• check tightening of drive elements and
reducer support
When
(hrs)
Action required Mach.
hrs
Operator Date
1500 and
every
1500 hrs
• change lubrication oil
• clean/replace filters (lubrication
system, pneumatic system, water
system)
• check drive belt wear, tensioning
and if required replace
• check wear of plungers and if
required replace
• check pressurization of pneumatic
system and oil level
• check oil level in gear reducer
3000 and
every
3000 hrs
• check / replace springs and
pumping valves
• check / replace homogenizing
valve
every
5000 hrs
• replace lubrication oil in gear
reducer (mineral oil)
4c010e0c.doc 4.2.2