Niro Soavi S.p.A
When
(hrs)
Action required Mach.
hrs
Operator Date
4500 change lubrication oil
clean/replace filters (lubrication
system, pneumatic system, water
system)
check drive belt wear, tensioning
and if required replace
check wear of plungers and if
required replace
check pressurization of pneumatic
system and oil level
6000 check / replace springs and
pumping valves
check / replace homogenizing
valve
7500 change lubrication oil
clean/replace filters (lubrication
system, pneumatic system, water
system)
check drive belt wear, tensioning
and if required replace
check wear of plungers and if
required replace
check pressurization of pneumatic
system and oil level
9000 check / replace springs and
pumping valves
check / replace homogenizing
valve
10500 change lubrication oil
clean/replace filters (lubrication
system, pneumatic system, water
system)
check drive belt wear, tensioning
and if required replace
check wear of plungers and if
required replace
check pressurization of pneumatic
system and oil level
12000 check / replace springs and
pumping valves
check / replace homogenizing
valve
4c010e0c.doc 4.2.3