1.1 TECHNICAL DATA SHEET
1 GENERAL
1.1 Serial Number 4759
1.2 Kind of Machine HOMOGENIZER
1.3 Model ARIETE
1.4 Type NS3018H
1.5 Execution Aseptic
1.6 Special Features CGMP+ELECTRUPOLISHED+3A+FDA
1.7 MAX Operating Pressure 1000 bar
1.8 Flow Rate Type V
1.9 MIN Flow Rate 150 l/h @ 15,5 Hz
1.10 MAX Flow Rate 500 l/h @ 51,6 Hz
1.11 MIN Feed Pressure 6-7 bar
1.12 MAX Backpressure 5 bar
2 OPERATING CONDITIONS
2.1 Product
CELL RUPTURE(PRODUCT
SOLUTION IN WATER)
2.2 MAX Viscosity 2-3 cP
2.3 MAX Relative Humidity 40 %
2.4 Ambient Temperature 40 °C
2.5 MAX Altitude 1000 m
2.6 MAX operating temperature 90 °C
2.7 MAX temperature CIP / SIP 140 °C
3 TECHNICAL FEATURES
3.1 COMPRESSION BLOCK
3.1.1 Type MULTIBLOCK VHP
3.1.2 Number of plungers 3
3.1.3 Material of plungers CERAMIC
3.1.4 Plunger diameter 20 mm
3.1.5 Stroke 70 mm
3.1.6 Pumping valve type PVB 3\4"
3.1.7 Overpressure valve
SPRING LOADED
VALVE
setpoint
1100
bar
3.1.8 Connection, Inlet 1" TRICLAMP
3.1.9 Connection, Outlet 1" TRICLAMP