Niro Soavi S.p.A
Refer to figure 4.6.2: to disassemble the pressure gauge (or pressure gauge
with transmitter, or pressure transducer) you need to loosen the nuts (G) and
pull out the pressure gauge complete with flange (F).
The pressure gauge (A) and flange (F) can be separated once the semi-rings
(D) have been removed.
Figure 4.6.3 shows the analog configuretion for disassembling the pressure
transducer.
FIGURE 4.6.2
Steps to be followed for assembly (figure 4.6.2 or 4.6.3):
- insert the gasket (E) on the pressure gauge rod (used only to protect from dirt)
-insert the gasket (G) inside its housing in the flange or head; food-grade
Vaseline or other suitable lubricants should be used for easier assembly
4c063e0c.doc 4.6.5