Niro Soavi S.p.A
In high-pressure versions, equipped with transducer (T) or digital pressure
gauge (M) (see figure 4.6.4), a threaded locking ring (D) is used.
FIGURE 4.6.4
For disassembly, unscrew the ring (D) and pull the instrument out; remove also
the gasket (B) and anti-extrusion rings (A, C) from their housing.
For assembly follow these steps (figure 4.6.4):
- fit anti-extrusion ring (C), gasket (B) and anti-extrusion ring (A) onto the
end of the pressure gauge (M) or transducer (T); food-grade Vaseline or
other suitable lubricants should be used for easier assembly
- fit the pressure gauge (M) or transducer (T) into its housing; with digital
pressure gauges make sure you do not force the element using the
head of the instrument to prevent breakages
- tighten the locking ring (D) fully
4c063e0c.doc 4.6.7