Niro Soavi S.p.A
TROUBLE
POSSIBLE CAUSE
REMEDY
10.Total lack of
homogenizing pressure
• Not enough flow • See trouble point 3
• Damaged
homogenizing valve
• Check, clean or
replace (Section 4 -
MAINTENANCE)
• No air pressure in
pneumatic circuit
• Check the pneumatic
circuit and the air supply
(Section 4 -
MAINTENANCE)
• Defective pneumatic
actuator
• Replace
11.Homogenizing
pressure not reached
• Not enough feeding
pressure
• Feed properly the
machine
• Blocked
homogenizing valve
• Disassemble and
clean (Section 4 –
MAINTENANCE)
• Worn out
homogenizing valve
• Replace (Section 4 –
MAINTENANCE)
• Faulty pressure gauge • Replace (Section 4 –
MAINTENANCE)
• Damaged
homogenizing valve
shaft
• Replace (Section 4 –
MAINTENANCE)
3C001E0C.DOC 3.8.4