Niro Soavi S.p.A
TROUBLE
POSSIBLE CAUSE
REMEDY
10.Total lack of
homogenizing pressure
Not enough flow See trouble point 3
Damaged
homogenizing valve
Check, clean or
replace (Section 4 -
MAINTENANCE)
No air pressure in
pneumatic circuit
Check the pneumatic
circuit and the air supply
(Section 4 -
MAINTENANCE)
Defective pneumatic
actuator
Replace
11.Homogenizing
pressure not reached
Not enough feeding
pressure
Feed properly the
machine
Blocked
homogenizing valve
Disassemble and
clean (Section 4 –
MAINTENANCE)
Worn out
homogenizing valve
Replace (Section 4 –
MAINTENANCE)
Faulty pressure gauge Replace (Section 4 –
MAINTENANCE)
Damaged
homogenizing valve
shaft
Replace (Section 4 –
MAINTENANCE)
3C001E0C.DOC 3.8.4