50940411/G0219 178 Printed in U.S.A.
522579 12 P1405 EGR Short-circuit between the EGR motor coils
522580 12 P0488 EGR EGR position sensor malfunction
522581 7 P148A EGR EGR stuck open valve malfunction
522582 7 P049D EGR EGR initialization malfunction
522583 1 P1410 EGR EGR high temperature thermistor malfunction
522584 1 P1411 EGR EGR low temperature thermistor malfunction
522585 12 P1613 ECU Internal Malfunction CY146 SPE/SPI communication error
522588 12 P1608 ECU Internal Malfunction Excessive supply 1 voltage error
522589 12 P1617 ECU Internal Malfunction Dropped/Insufficient supply 1 voltage error
522590 12 P1609 ECU Internal Malfunction Sensor supply voltage error 1
522591 12 P1618 ECU Internal Malfunction Sensor supply voltage error 2
522592 12 P1619 ECU Internal Malfunction Sensor supply voltage error 3
522593 12 P1624 ECU Internal Malfunction Power for sensor SRC low error
522594 3 P160A ECU Internal Malfunction Actuator drive circuit 1 VB short-circuit
522595 3 P1625 ECU Internal Malfunction Actuator drive circuit 2 VB short-circuit
522596 9 U0292 CAN 2 TSC1 (CAN message) reception time out (SA1)
522597 9 U1301 CAN 2 TSC1 (CAN message) reception time out (SA2)
522598 11 P160B ECU Internal Malfunction SW reset (recovery) execution 1
522599 9 U1292 CAN 2 Y_ECR1 (CAN message) reception time out error
522599 11 P1636 ECU Internal Malfunction SW reset (recovery) execution 2
522600 9 U1293 CAN 2 Y_EC (CAN message) reception time out error
522600 11 P1637 ECU Internal Malfunction SW reset (recovery) execution 3
522601 9 U1294 CAN 2 Y_RSS (CAN message) reception time out error
522601 12 P160D ECU Internal Malfunction WDA/ABE shut off due to dropped voltage
522602 12 P1639 ECU Internal Malfunction WDA/ABE shut off due to excessive voltage
522603 9 U1296 CAN 2 VH (CAN message) reception time out
522603 12 P1640 ECU Internal Malfunction WDA/ABE shut off due to unknown cause
522605 9 U1298 CAN 2 Y_ECM3 (CAN message) reception time out
522609 9 U1300 CAN 2 Y_ETCP1 (CAN message) reception time out
522610 9 U101B CAN 1 CAN1 (for EGR): Reception time out error
522610 19 U040C EGR CAN1 (for EGR): Reception data length error
522611 9 U1107 CAN1/Exhaust Throttle
Exhaust throttle (CAN message from the exhaust
throttle time out)
522617 12 U1401 EGR Valve EGR target value out of range
522618 9 U1302 CAN 2 EBC1 (CAN message) reception time out error
522619 9 U1303 CAN 2 Y_DPFIF (CAN message) reception time out
522623 7 P1647 Acceleration Sensor 1/2 Dual accelerator sensor (open position)
522624 7 P1646 Acceleration Sensor 1/2 Dual accelerator sensor (closed position)
522727 12 P1610 ECU Internal Fault Sub-CPU error A
522727 12 P1611 ECU Internal Fault Sub-CPU error B
522727 12 P1612 ECU Internal Fault Sub-CPU error C
522728 12 P1620 ECU Internal Fault Engine map data version error
Table 55: Yanmar Engine Diagnostic Trouble Codes (DTC)
DTC Error Item
SPN FMI P-Code Part State

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl RT210 and is the answer not in the manual?

Gehl RT210 Specifications

General IconGeneral
Rated Operating Capacity2, 100 lbs
Engine MakeYanmar
Tipping Load6000 lbs
Displacement202 cu in
Hydraulic Pressure3335 psi
Width72 in