EasyManuals Logo

Gehl RT210 User Manual

Gehl RT210
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #189 background imageLoading...
Page #189 background image
Troubleshooting
Printed in U.S.A. 179 50940411/G0219
522730 8 U1167 Immobilizer Pulse communication fault
522730 12 U0167 Immobilizer Communication fault
522744 4 P1626 ECU Internal Malfunction Actuator drive circuit 1 GND short-circuit
522746 12 P1438 Exhaust Throttle Voltage fault
522747 12 P1439 Exhaust Throttle Motor fault
522748 12 P1440 Exhaust Throttle Sensor system fault
522749 12 P1441 Exhaust Throttle MPU fault
522750 12 P1442 Exhaust Throttle PCB fault
522751 19 P1443 Exhaust Throttle CAN fault
522994 4 P1633 ECU Internal Malfunction Actuator drive circuit 2 GND short-circuit
522994 12 P1607 ECU Internal Malfunction WDA/ABE communication error
522994 12 P1615 ECU Internal Malfunction CY320 SPI communication error
522994 12 P1616 ECU Internal Malfunction MSC communication error of R2S2
523249 5 P0008 Cam Sensor No signal from both sensors
523460 7 P1670 Rail Pressure Control/Sensor
Rail pressure fault (operation time error during RPS
limp mode)
523462 13 P1648 Injector (Correction Value) IQA corrected injection amount for injector 1
523463 13 P1649 Injector (Correction Value) IQA corrected injection amount for injector 2
523464 13 P1650 Injector (Correction Value) IQA corrected injection amount for injector 3
523465 13 P1651 Injector (Correction Value) IQA corrected injection amount for injector 4
523468 9 P1665
PLV (Common Rail Pressure Limit
Value); Rail Pressure Sensor
Rail pressure fault (controlled rail pressure error
after PLV valve opening)
523469 0 P1666 Rail Pressure Sensor Rail pressure fault (PLV opening timing error)
523470 0 P1667 Rail Pressure Sensor Rail pressure fault (PLV opening timing error)
523471 6 P1467 ECU Internal Malfunction Actuator drive circuit 3 GND short-circuit
523473 12 P1469 ECU Internal Malfunction AD converter fault 1
523474 12 P1470 ECU Internal Malfunction AD converter fault 2
523475 12 P1471 ECU Internal Malfunction External monitoring IC and CPU fault 1
523476 12 P1472 ECU Internal Malfunction External monitoring IC and CPU fault 2
523477 12 P1473 ECU Internal Malfunction ROM fault
523478 12 P1474 ECU Internal Malfunction Shutoff path fault 1
523479 12 P1475 ECU Internal Malfunction Shutoff path fault 2
523480 12 P1476 ECU Internal Malfunction Shutoff path fault 3
523481 12 P1477 ECU Internal Malfunction Shutoff path fault 4
523482 12 P1478 ECU Internal Malfunction Shutoff path fault 5
523483 12 P1479 ECU Internal Malfunction Shutoff path fault 6
523484 12 P1480 ECU Internal Malfunction Shutoff path fault 7
523485 12 P1481 ECU Internal Malfunction Shutoff path fault 8
523486 12 P1482 ECU Internal Malfunction Shutoff path fault 9
523487 12 P1483 ECU Internal Malfunction Shutoff path fault 10
523488 0 P1484 ECU Internal Malfunction Recognition error of engine speed
523489 0 P1668
PLV (Common Rail Pressure Limit
Value); Rail Pressure Sensor
Rail pressure fault (the actual rail pressure is too
high during PRV limp mode)
Table 55: Yanmar Engine Diagnostic Trouble Codes (DTC)
DTC Error Item
SPN FMI P-Code Part State

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl RT210 and is the answer not in the manual?

Gehl RT210 Specifications

General IconGeneral
Rated Operating Capacity2, 100 lbs
Engine MakeYanmar
Tipping Load6000 lbs
Displacement202 cu in
Hydraulic Pressure3335 psi
Width72 in