Troubleshooting
Printed in U.S.A. 181 50940411/G0219
102-2
Charged air pressure error
Charged air pressure above warning threshold
Charged air pressure above shut-off threshold
102-3
Sensor voltage out of target range; sensor error
charged air pressure; signal range check high; short-
circuit to battery or open load
102-4
Sensor voltage out of target range; charged air
pressure sensor error; signal range check low; short-
circuit to ground
105-0
Sensor error
Charge air temperature downstream above target
range; charged air cooler temperature; system reaction
initiated, charge air temperature (downstream) over-
warning threshold; engine power loss or shutdown may
result
105-3
Charge air temperature sensor: sensor voltage out of
target range; charged air temperature sensor error;
signal range check high, short-circuit to battery or open
load
105-4
Charge air temperature sensor: sensor voltage out of
the target range; charged air temperature sensor error;
signal range check low; short-circuit to ground
107-0 Air filter sensor error
Air filter differential pressure: the pressure difference of
the intake air between the filter inlet and outlet above
target range, pressure value above warning threshold
111-1 Engine coolant temperature Coolant level too low
157-3
Rail pressure error
Measured sensor voltage out of target range; rail
pressure sensor error; signal range check high, short-
circuit to battery or open load
157-4
Voltage of sensor measured by ECU is out of the target
range; sensor error rail pressure; signal range check
high, short-circuit to battery or open load
168-0
Sensor error battery voltage
Battery voltage out of target range; physical range
check high for battery voltage; battery voltage over-
limit
168-1
Battery voltage out of target range; physical range
check low for battery voltage; battery voltage below
limit
168-3 Voltage above normal or shorted high
168-2 Voltage measured by ECU is out of the target range
168-4 Voltage below normal or shorted low
639-14 CAN Bus error CAN-Bus 0 "BusOff-Status"