Troubleshooting
50940411/G0219 182 Printed in U.S.A.
651-3
Electrical error
Current below normal or open circuit; injector cyl.1 (in
firing order); interruption of electric connection
652-3
Injector cyl. 3: the current drop measured by ECU is
above the target range; injector 2 short-circuit, injector
3 short-circuit
652-5
Injector cyl. 3: interruption of electrical connection;
injector cyl. 2, interruption of electric connection;
injector cyl. 3, interruption of electric connection;
653-3
Electrical error
Injector cyl. 4: voltage too high; injector cyl. 3 short-
circuit; injector cyl. 4 short-circuit
653-5
Voltage too low; Injector cyl. 4: interruption of electrical
connection; injector cyl. 3, interruption of electric
connection; injector cyl. 4, interruption of electric
connection;
654-3
Electrical error
Voltage above normal or shorted high; Injector cyl. 2:
the current drop measured by ECU is above the target
range; injector cyl. 4 short-circuit; injector cyl. 2 short-
circuit
654-5
Injector cyl. 2: interruption of electrical connection;
injector cyl. 4, interruption of electric connection;
injector cyl. 2, interruption of electric connection
677-3
Short-circuit
Start relay (high side powerstage): current drop/drain
above target range; starter relay; short-circuit, short-
circuit HighSide-output to battery or LowSide-Output to
battery
677-4
Start relay (high side powerstage): current drop/drain
above target range; starter relay; short-circuit, short-
circuit HighSide-output to ground or LowSide-Output to
ground
677-5 No load error
Start relay (low side powerstage): current drop above
target range; starter relay; no load error, Open circuit/
disconnection LowSide-Output
677-12 Powerstage over-temperature error
Start relay (low side powerstage): current drop above
target range; starter relay; powerstage over-
temperature
898-9 Timeout error Timeout error; limp mode activated
1079-13
ECU error
Internal hardware monitoring: deviation of target range
of power supply voltage of sensor output 1; sensor
supply voltage monitor 1 error (ECU), error in sensor
voltage 1
1080-13
Internal hardware monitoring: deviation of target range
of power supply voltage of sensor output 2; sensor
supply voltage monitor 2 error (ECU), error in sensor
voltage 2
1109-2 Engine shut-off error Engine shut-off demand ignored
1231-14 CAN BusOff error
CAN bus 1: the ECU not allowed to send messages,
because status "BusOff" is detected; "BusOff-Status",
CAN BusOff error; CAN 1 (engine/diagnostic CAN)
Table 56: Deutz Engine Error Codes
Error Code Engine Error Code Type Error Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl RT210 and is the answer not in the manual?

Gehl RT210 Specifications

General IconGeneral
Rated Operating Capacity2, 100 lbs
Engine MakeYanmar
Tipping Load6000 lbs
Displacement202 cu in
Hydraulic Pressure3335 psi
Width72 in

Related product manuals