Troubleshooting
Printed in U.S.A. 183 50940411/G0219
1237-2 Override switch error
ECU receives a permanent signal; Override switch;
plausibility error
523009-9
PRV error
Rail pressure relief valve: open frequency exceeds
specification; Pressure Relief Valve (PRV) reached
maximum allowed opening count; PRV needs to be
exchanged
523009-10
Rail pressure relief valve open longer than
specification allows; Pressure relief valve (PRV)
reached maximum allowed open time; PRV open
longer than 300 minutes
523350-4
Injector short-circuit
Injector cylinder-bank 1; short-circuit
523352-4 Injector cylinder-bank 2; short-circuit
523354-12 Injector error
Error of its injector high current output; Injector
powerstage output defect
523470-7
PRV error
Rail pressure out of expected average range;
Maximum rail pressure in limp home mode exceeded
(PRV), Monitoring for maximum rail pressure in limp
home mode with PRV
523470-2
Rising pressure forces pressure Relief Valve (PRV)
open; force-open fails
523470-11
Rail pressure relief valve can't be opened due to
railpressure; Pressure Relief Valve (PRV) error; rail
pressure out of tolerance range; averaged rail pressure
is outside the expected tolerance range
523470-12
Rail pressure relief valve open; Pressure Relief Valve
(PRV) forced to open; system reaction initiated, fault
path indicating shutoff condition in case of open PRV;
power reduction may result
523470-14
Rail pressure relief valve open; Pressure Relief Valve
(PRV) is open, Pressure relief valve (PRV) in rail is
open; power reduction may result
523550-12 T50 switch timeout
Terminal 50: ECU receives a permanent signal; T50
start switch active for too long, Startinformation to
Starter (T50-switch) erratic/defect; power reduction
may result
523601-13 (ECU) error
Internal hardware monitoring: deviation of target range
of power supply voltage of sensor output 3; sensor
supply voltage monitor 3 error (ECU), Error in sensor
voltage 3
523612-12
Software error
ECU internal software error; power reduction may
result
Internal ECU monitoring detection reported error
523612-14
Internal hardware monitoring: ECU CPU reset and
cause is logged internally; no item created in error
memory; software reset CPU, software visibility resets
in DSM
Table 56: Deutz Engine Error Codes
Error Code Engine Error Code Type Error Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl RT210 and is the answer not in the manual?

Gehl RT210 Specifications

General IconGeneral
Rated Operating Capacity2, 100 lbs
Engine MakeYanmar
Tipping Load6000 lbs
Displacement202 cu in
Hydraulic Pressure3335 psi
Width72 in