Page #194 background imageLoading...
Page #194 background image
Troubleshooting
50940411/G0219 184 Printed in U.S.A.
523613-0
Rail pressure error
Rail pressure: fuel pressure in rail below target range
dependant on engine speed; rail pressure disrupted,
positive governor deviation; maximum positive rail
pressure deviation exceeded concerning set fuel flow;
power reduction may result
Rail pressure: fuel pressure in rail exceeds target
range dependant on engine speed; rail pressure
disrupted, maximum negative rail pressure deviation
with metering unit on lower limit is exceeded
Rail pressure: fuel pressure in rail exceeds target
range dependant on engine speed; rail pressure
disrupted, leakage detected based on fuel quantity
balance; power reduction may result
Rail pressure: fuel pressure in rail exceeds target
range dependant on engine speed; rail pressure
disrupted, maximum rail pressure exceeded
523613-1
Rail pressure: fuel pressure in rail below target range
dependant on engine speed; minimum rail pressure
exceeded
523613-2 Metering unit error
Rail pressure: fuel pressure in rail exceeds target
range dependant on engine speed; metering unit
setpoint in overrun mode not plausible; power
reduction may result
523615-3
Short-circuit
Current drain above target range; metering unit (fuel
system); short-circuit to battery high/low side; power
reduction may result; power reduction may result
523615-4
Current drain below target range; metering unit (fuel
system); short-circuit to battery high/low side; power
reduction may result
523615-5 Fuel system error
Fuel metering unit: the ECU detects no load or
temperature excess of the ECU component for power
supply of the valve; Metering unit (fuel system); open
load; power reduction may result
523698-11 SCR error Engine shut-off due to supervisory function
523776-9 Timeout error Timeout error; limp mode activated
523895-13
Injector adjustment error
Missing or wrong injector adjustment value
programming (IMA) injector 1 (in firing order)
523896-13
Missing or wrong injector adjustment value
programming (IMA) injector 2 (in firing order)
523897-13
Missing or wrong injector adjustment value
programming (IMA) injector 3 (in firing order)
523898-13
Missing or wrong injector adjustment value
programming (IMA) injector 4 (in firing order)
Table 56: Deutz Engine Error Codes
Error Code Engine Error Code Type Error Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl RT210 and is the answer not in the manual?

Gehl RT210 Specifications

General IconGeneral
Rated Operating Capacity2, 100 lbs
Engine MakeYanmar
Tipping Load6000 lbs
Displacement202 cu in
Hydraulic Pressure3335 psi
Width72 in

Related product manuals