GWN7000 User Manual
Version 1.0.6.28
MAINTENANCE AND TROUBLESHOOTING
GWN7000 offers multiple tools and options for maintenance and debugging to help further troubleshooting
and monitoring the GWN7000 resources.
Maintenance
Maintenance page can be accessed from GWN7000 WebGUI→System Settings→Maintenance.
Maintenance page includes different tabs: Basic, Upgrade, Access, Syslog and Logserver.
Basic
Table 45: Maintenance - Basic
Anti-domain name hijacking protection.
If enabled, when the address returned by the superior DNS is a private LAN
address, it will be regarded as a domain name hijacking, thus discarding the
analytical result.
If disabled, the analytical result will not be discarded.
Enable the web WAN access. By default, it’s disabled
Enable the web HTTP Access. By default, it’s disabled.
Specifies the HTTPS port. By default, is 443.
Select the country from the drop-down list.
Configure time zone for the GWN7000.
Please reboot the device to take effect.
Configure the IP address or URL of the NTP server, the device will obtain the
date and time from the configured server.
Change the Date Display Format, three options are possible YYYY/MM/DD,
MM/DD/YYYY and DD/MM/YYYY
Upgrade
Table 46: Maintenance - Upgrade
Authenticate configuration file before acceptance. Default is disabled.
Enter the password for encrypting the XML configuration file using OpenSSL.
The password is used to decrypt the XML configuration file if it is encrypted.
Specify uploading method for firmware and configuration. 3 options are
available: HTTP, HTTPS and TFTP.