Page #146 background image
134
Settings made in Ethernet interface view or Layer 2 aggregate interface view take effect only on the
current port; settings made in port group view take effect on all ports in the port group.
Before enabling BPDU tunneling for DLDP, EOAM, GVRP, HGMP, LLDP, or STP on a port, disable the
protocol on the port.
To enable BPDU tunneling for PVST (which is an spanning tree protocol) on a port, disable STP first and
then enable BPDU tunneling for STP on the port.
Before enabling BPDU tunneling for LACP on a member port of a link aggregation group, remove the
port from the link aggregation group.
Examples
# Disable STP on GigabitEthernet 1/0/1, and then enable BPDU tunneling for STP on the port.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] undo stp enable
[Sysname-GigabitEthernet1/0/1] bpdu-tunnel dot1q stp
# Disable STP for port group 1, and then enable BPDU tunneling for STP in the port group.
<Sysname> system-view
[Sysname] port-group manual 1
[Sysname-port-group-manual-1] group-member gigabitethernet 1/0/1 to gigabitethernet
1/0/6
[Sysname-port-group-manual-1] undo stp enable
[Sysname-port-group-manual-1] bpdu-tunnel dot1q stp
# Disable STP on Layer 2 aggregate interface 1, and then enable BPDU tunneling for STP on the port.
<Sysname> system-view
[Sysname] interface bridge-aggregation 1
[Sysname-Bridge-Aggregation1] undo stp enable
[Sysname-Bridge-Aggregation1] bpdu-tunnel dot1q stp
bpdu-tunnel tunnel-dmac
Syntax
bpdu-tunnel tunnel-dmac mac-address
undo bpdu-tunnel tunnel-dmac
View
System view
Default level
2: System level
Parameters
mac-address: Destination multicast MAC address for BPDUs, in the format of H-H-H. The allowed values
are 0x0100-0CCD-CDD0, 0x0100-0CCD-CDD1, 0x0100-0CCD-CDD2, and 0x010F-E200-0003.
Description
Use the bpdu-tunnel tunnel-dmac command to configure the destination multicast MAC address for
BPDUs.
Use the undo bpdu-tunnel tunnel-dmac command to restore the default value.

Table of Contents

Other manuals for H3C S5120-EI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5120-EI Series and is the answer not in the manual?

H3C S5120-EI Series Specifications

General IconGeneral
BrandH3C
ModelS5120-EI Series
CategorySwitch
LanguageEnglish

Related product manuals