EasyManua.ls Logo

H3C S5120-EI Series - Garp Timer Hold

H3C S5120-EI Series
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
191
Default level
0: Visit level
Parameters
interface interface-type interface-number: Specifies an interface by its type and number.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see the Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, which is a case sensitive string of 1 to 256 characters.
Description
Use the display gvrp vlan-operation command to display information about dynamic VLAN operations
on a port.
Examples
# Display information about dynamic VLAN operations on GigabitEthernet 1/0/1.
<Sysname> display gvrp vlan-operation interface gigabitethernet 1/0/1
Dynamic VLAN operations on port GigabitEthernet1/0/1
Operations of creating VLAN : 2-100
Operations of deleting VLAN : none
Operations of adding VLAN to TRUNK : 2-100
Operations of deleting VLAN from TRUNK : none
garp timer hold
Syntax
garp timer hold timer-value
undo garp timer hold
View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default level
2: System level
Parameters
timer-value: Hold timer setting (in centiseconds), which must be a multiple of 5 in the range of 10
(inclusive) and half of the Join timer setting (inclusive). One second equals 100 centiseconds.
Description
Use the garp timer hold command to set the GARP Hold timer for an Ethernet port, Layer-2 aggregate
interface, or all ports in a port group.
Use the undo garp timer hold command to restore the default of the GARP Hold timer. This may fail if the
default is beyond the valid value range for the Hold timer.
By default, the Hold timer is set to 10 centiseconds.

Table of Contents

Other manuals for H3C S5120-EI Series

Related product manuals