EasyManua.ls Logo

H3C S5120-EI Series - Garp Timer Leaveall

H3C S5120-EI Series
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
193
Default level
2: System level
Parameters
timer-value: Leave timer setting (in centiseconds), which must be a multiple of 5 between two times the
Join timer (exclusive) and the LeaveAll timer setting (exclusive).
Description
Use the garp timer leave command to set the GARP Leave timer for an Ethernet port, Layer-2 aggregate
interface, or all ports in a port group.
Use the undo garp timer leave command to restore the default of the GARP Leave timer. This may fail if
the default is beyond the valid value range for the Leave timer.
By default, the Leave timer is set to 60 centiseconds.
Related commands: display garp timer, garp timer join, and garp timer leaveall.
Examples
# Set the GARP Leave timer to 100 centiseconds, assuming that both the Join timer and the LeaveAll timer
are using the default.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] garp timer leave 100
garp timer leaveall
Syntax
garp timer leaveall timer-value
undo garp timer leaveall
View
System view
Default level
2: System level
Parameters
timer-value: Leaveall timer setting (in centiseconds), which must be a multiple of 5 in the range of the
maximum Leave timer on the switch (exclusive) and 32765 (inclusive).
Description
Use the garp timer leaveall command to set the GARP LeaveAll timer.
Use the undo garp timer leaveall command to restore the default. This may fail if the default is beyond
the valid value range for the LeaveAll timer.
By default, the setting of the LeaveAll timer is 1000 centiseconds.
Related commands: display garp timer and garp timer leave.
Examples
# Set the leaveall timer to 100 centiseconds, assuming that the Leave timer on every port is set to 60
centiseconds.

Table of Contents

Other manuals for H3C S5120-EI Series

Related product manuals