6-6 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
Maxiva ULX COFDM Series
Exciter B Power
Output
Exciter B power
level low
Trip point is 50% of
nominal. Trip point
adjustable by epot
Exciter Switch
to alternate
Exciter if in
Auto Mode
NO YES
EXCA NO COMMU-
NICATIONS
Exciter A not com-
municating with
transmitter main
controller
No serial communica-
tions traffic detected
Exciter Switch
to alternate
Exciter if in
Auto Mode
NO NO
EXCB NO COMMU-
NICATIONS
Exciter B not com-
municating with
transmitter main
controller
No serial communica-
tions traffic detected
Exciter Switch
to alternate
Exciter if in
Auto Mode
NO NO
EXCA Summary
Fault
Exciter A reports a
summary fault
Exciter Switch to alter-
nate Exciter if in Auto
Mode
NO YES
EXCB Summary
Fault
Exciter B reports a
summary fault
Exciter Switch to alter-
nate Exciter if in Auto
Mode
NO YES
Table 6-1 Maxiva Drive Chain Fault List
TYPE Description Fault Level or
Threshold
Transmitter
Action
Three
Strike
Available
in Life
Support

Table of Contents