Menu 1. AUTOMATIC Command reference
EN 3925-0060 V207-00 MANUAL R03.doc
HeMaTech
Prüftechnik
Automatic mode without leak simulation
In automatic mode the device is operated through a machine control interface. For
more details please refer to chapter
Exchange of signals with the machine control
.
Automatic mode with leak simulation (option)
In addition to the operation described in section SETUP/Test Program you must ap-
ply the signal Leak to X21/3 from the machine control, before the signal Machine
ready is applied.
Automatic mode static test (flooding)
If the signal Static Test X21/4 is applied instead of the signal Start X21/2, the speci-
men will be exposed to the test pressure determined in the parameter set of the select-
ed program. The specimen is kept pressurized, as long as the signal Static Test is
applied.