Figure 9-7 Array List
9.2.2 Rebuild an Array
The array status includes Funconal, Degraded, and Oine. To ensure the high security and
reliability of the data stored in an array, take immediate and proper maintenance of the arrays
according its status.
Funconal
No disk loss in the array.
Oine
The number of lost disks has exceeded the limit.
Degraded
If any HDD fails in the array, the array degrades. Restore it to Funconal status by rebuilding the
array.
Congure
a Hot Spare Disk
The hot spare disk is required for the disk array automac rebuilding.
Steps
1.
Go to Storage → RAID Setup → Physical Disk .
Figure 9-8 Physical Disk
2.
Click of an available HDD to set it as the hot spare disk.
Automacally
Rebuild an Array
The video recorder can automacally rebuild degraded arrays with the hot spare disks.