172
_____________________________________________________________________
9.1 Using the A/B Cursors
______________________________________________________________
Indicates position of Trigger point,
A and B cursors
Waveform display
portion
All recording length
Display Meaning
A t=8.37ms
Time from the trigger point to A cursor
1/t = 119.4 Hz
Frequency taking t as the period
B t=16.75s
Time from the trigger point to B cursor
1/t = 59.7 Hz
Frequency taking t as the period
B-A t=8.37ms
Time interval between the A and B
cursors
1/t = 119.4 Hz
Frequency taking time interval between
the A and B cursors as the period
9.1 Using the A/B Cursors
The A/B cursors can be used to read a time difference,
frequency, or potential difference on screen. (When scaling
is used, the values are displayed in the scaling value. Refer
to Section 7.5.)
When using the vertical line cursors as shown in the figure below.