Slot No. indicator Component Server blade
B-nn-Lz
3
LOM CB 540A B1
B-nn-OB LOM CB 520X B1/B2/B3
Notes:
1. x indicates the mezzanine slot number and the value is 1 or 2.
2. y indicates the mezzanine slot number and the value is 1, 2, 3 or 4.
3. z indicates the LOM number and the value is 1 or 2.
Note
Update the firmware of the replaced CNA/LAN mezzanine card
according to the following criteria.
1. When the firmware version of failed CNA/LAN mezzanine card was
confirmed before the replacement, apply the confirmed version onto
the replaced Emulex CNA/LAN mezzanine card.
2. When the firmware version of failed CNA/LAN mezzanine card was
not confirmed or was indicated as No history before the replacement,
and other CNA/LAN mezzanine cards or LOM are installed in the
server blade, apply the version of other mezzanine cards or LOM.
3. When the firmware version of failed CNA/LAN mezzanine card was
not confirmed or was indicated as No history before the replacement,
and neither CNA/LAN mezzanine cards nor LOM except the replaced
CNA product is installed in the server blade, identify an appropriate
firmware version of CNA product according to the server blade type
and its firmware version. For details, see the following table.
Blade
To be applied CNA FW version
Type FW version
CB 520A A1 < 02-51 4.2.433.604
02-51 ≤ Latest version
CB 520H A1/B1 < 01-92 4.2.433.604
01-92 ≤ Latest version
CB 540A A1/B1 < 03-25 4.2.433.604
03-25 ≤ Latest version
CB 520H B2/B3/B4 N/A Latest version
CB 520X B1/B2/B3 N/A Latest version
Perform the following steps only when the updating firmware is
required.
9. Enter 2 in Select No. line of Emulex CNA Utility dialog box, and then
press Enter.
Configuring Emulex mezzanine card
7-75
Hitachi Compute Blade 500 Series System Service Manual