128 MPA2C3 User Manual
Step 3. Navigate to the "Advanced" Tab of the primary panel:
RS-485 Installations: Secondary panels will automatically register with the
Gateway.
Confirm the secondary panels are registered.
EVL Installations: Requires Manual Registration of the Secondary Panels.
Navigate to the EVL Discovery and "Register" the Secondary Panels.
IMPORTANT: In order to proceed to Step #4 please wait for all panels to be syn-
chronized. Refer to the "Synchronization Detail Chart"
Step 4. Select the "Restore Entire Loop" option from the "System Wide Backup"
once all of the Secondary panels are registered with the Primary.
• Refer to the "Restore Entire Loop Detail Chart"
Replace a Secondary Panel (Web Mode)
Overview
Details the steps to replace a MPA2C3C3 "Secondary" panel in an existing loop of
either a wired via RS-485 or Ethernet Virtual Loop (EVL) in Web Mode.
Secondary Panel Replacement and Synchronization
Step 1. Un-register the original Secondary panel in the Primary panel. Navigate
to:
• RS-485 Unregister Tab: Panel Configuration > Advanced > RS-485 Unregister.
• EVL Tab: Menu > Panel Configuration > Advanced > EVL Discovery.
Step 2. Install the replacement Secondary panel in the loop.
Step 3. Navigate to the "Advanced" Tab of the primary panel:
• RS-485 Installations: Secondary panels will automatically register with the
Gateway.
• Confirm the secondary panels are registered.
• EVL Installations: Requires Manual Registration of the Secondary Panels.
• Navigate to the EVL Discovery and "Register" the Secondary Panels.
IMPORTANT: In order to proceed to Step #4 please wait for the Secondary panel
to be synchronized. Refer to the "Synchronization Detail Chart"
Step 4. Program and add the new Secondary panels doors into the "Spaces".
Step 5. Program the custom settings for Readers, Input Points and Output
Points.
Step 6. Perform a "System Wide Backup" when programming is complete.