8114A Specifications
Duty-cycle
0.1% to
100%
(Subject to width and period specifications).
Standard HP 8114A (Baseline = 0 V)
01
10
20 I
30
40 50 v
1V
28.1V
Amplitude (50 Ohm into 50 Ohm)
WA
Specified Operating Range (Single Pulses)
Figure 2-1. Duty-cycle
/
Amplitude Ranges
Figure 2-l shows the maximum possible duty-cycle for a given pulse
amplitude from
5052
into 5061. Note that amplitude doubles from HIZ
(High-Z) into 508.
In double-pulse mode the actual duty-cycle of the signal is twice the
value displayed on the HP 8114A screen because two pulses are
generated per pulse period. Therefore, the duty-cycle available, and
set,
will
be limited to half the value given by Figure 2-1.
HP
8114A
Pulse Generator
2-7